For heat-resistant borescopes that exceed 150℃, we cover them with a heat-resistant jacket (custom-made product).
Insert water for cooling and air for tip purge into the heat-resistant jacket.
In other words, a chiller device (low-temperature circulation high-temperature water tank) that circulates cooling water is required.
Set the water cooling outlet of the heat-resistant jacket so that the temperature is approximately 60℃ or less.
We can also propose a chiller device (low-temperature circulation high-temperature water tank) that circulates cooling water.
We will have a detailed meeting with the customer, but the following information is required at a minimum.
① Distance from chiller device → water cooling inlet
②Water cooling outlet → Distance to chiller device
③Height difference between chiller device and borescope mounting position
④ Size of heat-resistant jacket, etc.